Search Pharmacy 2011

Showing posts with label Hospital Pharmacy. Show all posts
Showing posts with label Hospital Pharmacy. Show all posts

Sunday, January 23, 2011

QUALITY CONTROL TESTS FOR SUTURES AND LIGATURES


1)    GAUGE TEST:
For checking the diameter of the catgut, the dial reading type gauge is used. The diameter is taken in a relative humidity between 60%-80% and temperature range 16-21oC.
The finest size is 1, which is used for ophthalmic work and the largest size is 10, which is used for other surgical procedures.

2)    LENGTH:
This is measured immediately after the removal of suture from the container without stretching. The length should not be less than 90% of the stated length on the label.

3)    TENSILE STRENGTH:
It is done by means of machine in which (Load necessary to rupture the GUT) is measured. The test is performed on straight and knotted sample. The suture is tested within 15 minutes of the removal from the container at a temperature 10-21oC and relative humidity 60%-80%.

4)    STERILITY TEST:
A medium is prepared which can detect the presence of aerobic and anaerobic organisms. If after an incubation period of 14 days, no growth of the micro-organisms is found in any tube, the sample passes the test.
If the growth occurs, another sample is taken and the test is repeated. If the growth occurs, the catgut fails in sterility test.

BOILABLE AND NON-BOILABLE CATGUT



BOILABLE CATGUT:
i)                   The boilable catgut is prepared by heat sterilization method.
ii)                 The tubing fluid is anhydrous e.g. Toluene.
iii)               The tubes are boiled before opening by Operation Theater staff.

NON-BOILABLE CATGUT:
i)                   If the tubing fluid contains any hydrous liquid, the catgut is called as non-boilable.
ii)                 Outside of the tube is not boiled before opening of the tube.
iii)               Official catgut is of non-boilable type.

STERILIZATION OF THE CATGUT


The intestine of sheep is infected with bacteria e.g. E-coli, Streptococcus faecalis and the dangerous anaerobic spore-forming organisms e.g. bacillus anthracis and those bacteria which cause tetanus and which cause Gas Gangrene.

METHODS USED FOR STERILIZATION:
1-CHEMICAL METHOD:
It employs a material which is sporocidal. The main chemicals used are Formaldehyde, Hydrogen Peroxide, Methyl Iodide, Iodine and Ethylene Oxide.
Iodine is the most commonly used chemical.
PROCESS:
It consists of emersion of standard length of catgut which is wound on a frame in a standardized aqueous solution of iodine and potassium iodide. The catgut is then transferred to a sterile solvent to remove the excess of iodine. The sterile strands are then transferred under aseptic conditions to the final container containing 95% ethanol and sealed.

2- RADIATION METHOD:
It is commonly employed method.
PROCEDURE:
Prepared gut is packed in aluminum foil envelope containing 90% Isopropyl Alcohol (I.P.A).
The envelopes are then passed through radiation area on a conveyer belt. The catgut is sterilized when it is sealed in the final container. The external surface of the envelope is sterilized before opening by emersion in a solution of 1% Formaldehyde and 90% Isopropyl Alcohol (I.P.A).

ELECTRON PARTICLES OR GAMMA RAYS:
Usually 2.5 megarad is used for the sterilization. Now-a-days this type of sterilization is done on the final sealed container, containing suture and ligatures.



HEAT STERILIZATION:
The raw catgut contains about 20% moisture. Heating above 80oC results in hydrolysis of collagen which is then converted into gelatin and catgut becomes useless. Therefore before heat sterilization, moisture from the catgut is removed by slow drying.

PROCEDURE:
The process is as follow:
i)                   TUBING: Suitable length of the catgut is coiled and placed in glass tubes.
ii)                  DRYING: The tubes are placed in basket and are dried in oven in which the temperature is slowly raised until completely dried. The sterilization is done by one of the two methods.

METHOD 1:
The baskets of tubes are placed in an autoclave and catgut is covered with organic fluid (Toluene) of high boiling point and the temperature is raised to about 160oC. No pressure is applied.

METHOD 2:
The tubes are subjected to the vapors of organic fluid (Toluene of Xylol) under pressure and the temperature is raised to 160oC for suitable time period.
After sterilization, the tubes are allowed to cool and filled with a sterile tubing fluid e.g. hydrated sterile alcohol to put back the necessary moisture.
It is sealed by the fusion of glass and whole process is done aseptic conditions.

THE PRODUCTION OF SUTURES AND LIGATURES

RAW MATERIAL:

The first 7.5 meter of intestine is selected and used.

SELECTION AND WASHING:

Clean the intestine by soaking into water which is done repeatedly until the casings are as clean as possible.

SPLITTING THE CASINGS:

Casings are split into smooth and rough ribbons. The smooth ribbons are selected for surgical catgut.

REMOVAL OF UNWANTED LAYERS:

The GUT consists of 4 layers, serosa, musculosa, submucosa and mucosa. The submucosa layer is scrapped away mechanically by knives by soaking into alkaline solution.

ORIENTATION OF FIBERS:

The fivers are arranged in parallel way. It greatly increases tensile strength (it is the load necessary to rupture the GUT by machines).

HARDENING:

It is done by soaking into chromic salt solutions.

Following types are available:

i) Plain

ii) Chromic

iii) Extra-chromic

Hardening causes the delay in the absorption of catgut inside the body. The time of absorption depends upon the strength of chromic salt solution used.

SPINNING:

If there is over-spinning, there will be lack of elasticity of catgut. If there is under-spinning, there will be too much elasticity. So the spinning should be optimum in order to obtain catgut of suitable elasticity. The no. of twists used in spinning must ensure uniform product of good tensile strength.

DRYING:

It is done in atmospheric conditions with respect to temperature and relative humidity.

FINISHING:

The dried strings are polished by mechanically means. This step is really a smooth process where the strings are rubbed against abrasive surfaces to produce smooth and uniform strings.

GAUGING:

Gauge is carefully checked and it should show uniformity.

STERLIZATION:

It is done by

i) Heat

ii) Chemical methods

iii) Ionization radiation

PACKAGING:

STORAGE AND LABELING: